Planet Technology POE-1200 User Manual

Browse online or download User Manual for Gateways/controllers Planet Technology POE-1200. Planet Technology POE-1200 User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Web Management Injector Hub

User’s Manual POE-1200 POE-

Page 2 - Trademarks

7 Figure 2-4 POE-2400 Rear Panel Power Notice: 1. The device is a power-required device, it means, it will not work till it is powered. If your ne

Page 3 - TABLE OF CONTENTS

8 Step5: Supply power to the PoE Injector Hub. A. Connect one end of the power cable to the PoE Injector Hub. B. Connect the power plug of the powe

Page 4 - 1. INTRODUCTION

9 Figure 2-6 Mounting thePoE Injector Hub in a Rack Step6: Proceeds with the steps 4 and steps 5 of session 2.2.1 Desktop Installation to connect t

Page 5 - 1.3 How to Use This Manual

10 Figure 2-7 Network application installation The PoE Injector Hub supports Data passive mode, that is, even the PoE Injector Hub is manual power

Page 6 - 1.4 Product Features

11 3 MANAGEMENT This chapter describes how to manage the Web Smart PoE Injector Hub. Topics include: - Overview - Management method - Logging on to

Page 7 - 1.5 Product Specifications

12 Figure 3-1 Web Management over Ethernet 2. When the following login screen appears, please enter the default username "admin" and pass

Page 8 - 2. INSTALLATION

13 3.3.2 PLANET Smart Discovery Utility For easily list the PoE Injector Hub in your Ethernet environment, the Planet Smart Discovery Utility from us

Page 9 - 2.1.3 Injector Rear Panel

14 4. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version, Device IP Subnet address, al

Page 10 - 2.2.1 Desktop Installation

15 4 WEB CONFIGURATION The PoE Injector Hub provide Web interface for PoE smart function configuration and make the PoE Injector Hub operate more eff

Page 11 - 2.2.2 Rack Mounting

16 4.2 Web Panel At the top of the Web management page, the active panel displays the link status of management port and PoE ports. Figure 4-2 Main

Page 12

2 Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is a registered trademark of P

Page 13

17 4.3.1 System Information The System information allows viewing system MAC Address, Software Version, Hardware Version, IP Address, Subnet Mask and

Page 14 - 3 MANAGEMENT

18 The page includes the following configurable data: Object Description Choose what the PoE Injector Hub should do following power-up: transmit a

Page 15

19 4.4 PoE  Power Management: In a power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN

Page 16

20 PoE Function Can enable or disable the PoE function. Priority Set port priority for the POE power management It can choose the “port priority”,

Page 17

21 4.5 Tools This function displays the PoE Injector Hub tools; include “System Reboot”, “Configuration Setting”, “Alert trap Configuration” and “Fir

Page 18 - 4 WEB CONFIGURATION

22 4.5.2 Configuration Setting This function allows backup and restore the current configuration of PoE Injector Hub, or reset the converter to facto

Page 19 - 4.3 System

23 Restore The PoE Injector Hub will restore to previous backup/saved configuration while the “Restore” button be pressed. And please note that on

Page 20 - 4.3.2 IP Configuration

24 4.5.3 Alert Trap Configuration This function displays the PoE Injector Hub alert trap configuration; include “enable” or “disable” the trap mode a

Page 21 - 4.3.3 Password Setting

25 4.5.4 Firmware Upgrade This section provides firmware upgrade of PoE Injector Hub, after choose this function and the following screen appears in

Page 22 - 4.4 PoE

26 Figure 4-19 Firmware Upgrade screen Do not power off the PoE Injector Hub until the update progress is complete. Do not quit the Firmware Upg

Page 23

3 TABLE OF CONTENTS 1. INTRODUCTION...

Page 24 - 4.5 Tools

27 Figure 4-21 Login screen

Page 25 - 4.5.2 Configuration Setting

28 5. POWER OVER ETHERNET OVERVIEW What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet, the most widely in

Page 26 - Factory Reset

29 The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isol

Page 27 - PoE SNMP Trap event

30 6. THE POE PROVISION PROCESS While adding PoE support to networked devices is relatively painless, it should be realized that power cannot simply

Page 28 - 4.5.4 Firmware Upgrade

31 6.3 Start-up Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full voltage capaci

Page 29 - 4.6 Logout

32 7 TROUBLESHOOTING This chapter contains information to help you solve problems. If the Device is not functioning properly, make sure the Ethernet

Page 30 - Figure 4-21 Login screen

33 APPENDIX A A.1 MDI Settings The Medium-Dependant Interface (MDI or RJ-45) serves as the data/power interface between Ethernet elements. As such, i

Page 31 - What is PoE?

34 A.3 DATA OUT PoE Injector RJ-45 Port Pin Assignments PIN NO RJ-45 SIGNAL ASSIGNMENT 1 Output Transmit Data + 2 Output Transmit Data - 3 Receiv

Page 32

35 Before you powered PD, please check the RJ-45 connector pin assignment follow IEEE 802.3af standard, otherwise you may need change one of the RJ-4

Page 33 - 6. THE POE PROVISION PROCESS

36 APPENDIX B B.1 Power over Ethernet Compatibility test No. PDs PoE Output Note 1 [PLANET POE-151S-12V] + [PLANET ICA-500] 9.6W 2 [PLANET PO

Page 34 - 6.4 Operation

1 1. INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● IEEE 802.3af Power over Ethernet Injector Hub x1 ●

Page 35 - 7 TROUBLESHOOTING

PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T

Page 36 - APPENDIX A

PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T

Page 37 - RJ-45 assignment

2 Figure 1-1 Power over Ethernet Application 1.3 How to Use This Manual This Web Smart Power over Ethernet Injector Hub User Manual is structure

Page 38

3 1.4 Product Features  Interface  24 / 48-Port RJ-45 STP ¾ 12 / 24-Port “Data input” ¾ 12 / 24-Port “Data + Power output”  1 10/100Base-TX Ma

Page 39 - APPENDIX B

4 1.5 Product Specifications Product POE-1200 POE-2400Hardware Specification“Data” Input Ports12 x RJ-45 STP 24 x RJ-45 STP “Data+Power” Output Po

Page 40 - EC Declaration of Conformity

5 2. INSTALLATION This section describes the hardware features and installation of these PoE Injector Hub on the desktop or rack mount. For easier m

Page 41

6 The following is the summary table of Reset button functions: Reset Button Pressed and Released Function About 1 second Reboot the PoE Injector H

Comments to this Manuals